| Name |
| ||
| Technical purpose of product or process | MicroVent is a decentralized ventilation system integrated in the building façade. The principle of a micro-ventilation system is that at least two micro-ventilation units work together to exchange the air in a room. The units are coordinated in such a way that when one unit removes air, another unit will supply air to the room. Micro-ventilation can be used in most buildings and is particularly suitable for renovation projects due to its simple installation process - even in protected and historically valuable buildings. | ||
| Classification |
Class name
:
Hierarchy level
| ||
| General comment on data set | MicroVent is a decentralized ventilation system integrated in the building façade. Incl. Add-on Steel Screens for internal and external use | ||
| Copyright | Yes | ||
| Owner of data set | |||
| Quantitative reference | |||
| Reference flow(s) |
| ||
| Biogenic carbon content |
| ||
| Time representativeness | |||
| Data set valid until | 2029 | ||
| Time representativeness description | valid from 2024-09-26 - 2029-09-26 | ||
| Technological representativeness | |||
| Technology description including background system | The air handling units follow the standards: EN 13141-7 / EN 13141-8. The declared products are used for demandcontrolled balanced, comfort ventilation with heat recovery in residential, office, institutional, and other occupancy and residential spaces. The product complies with applicable legal requirements for specific energy consumption (SEL value) and heat recovery. The products comply with Danish Building regulations BR 2018 and BK2020, Ecodesign and DS447. The products are tested and comply with the regulations according to DS/EN 13141-8 for one AHU unit: • Temperature efficiency The temperature efficiency test is according to DS/EN 13141-8: 8.1 General calculations and DS/EN 13141-8: 5.4.7.3 Thermal test and DS/EN 13141-8: 8.2 Special calculations for alternating exchangers. - w of the internal leakage (not measured) - x of the outdoor mixing (not measured) - y of the indoor mixing (not measured) - v of the air flow sensitivity (not measured) Delivery reservation (delimitation / limitation): This test was carried out according to DS/EN 13141 – 8. Further technical information can be obtained by contacting the manufacturer or on the manufacturer’s website: https://maico-nordic.dk/ Foreground system: The product is produced using a mix of Danish residual electricity mix from 2022 (76.12%) and electricity from solar panels on-site (23.88%) from 2023 in the production. Remaining energy processes is modelled using national electricity mixes from Managed LCA Content (MLC) database. Background system: Upstream processes are modelled using national energy mixes. Downstream processes are modelled using national energy mixes. | ||
| Type of data set | EPD | ||||
| Subtype | specific dataset | ||||
| Data sources, treatment and representativeness | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
| Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
| Data generator | |
| Data set generator / modeller | |
| Data entry by | |
| Time stamp (last saved) | 2026-04-21T13:48:47.255+01:00 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 3cb4e3e6-6238-4b94-af1d-e3190f60424a |
| Date of last revision | 2026-04-15T00:00:00.000 |
| Data set version | 00.01.002 |
| Registration authority | |
| Registration number | MD-24121-EN_rev2 |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | none |
Indicators of life cycle