Close Go back Collapse all sections
Process Data set: Thatched roof (en) en da

Key Data Set Information
Location RER
Reference year 2024
Name
Thatched roof
Technical purpose of product or process The thatched roof is used as roof covering on pitched roofs.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 2.23 Dämmstoffe / Stroh
General comment on data set The thatched roof is used as roof covering on pitched roofs. The LCI and LCIA results in this EPD relates to 1m2
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • grammage: 45.8 kg/m^2
    • conversion factor to 1kg: 0.0218 -
Biogenic carbon content
  • Carbon content (biogenic): 20.92 kg
  • Carbon content (biogenic) - packaging: 0.0 kg
Time representativeness
Data set valid until 2029
Time representativeness description valid from 2024-02-22 - 2029-02-22
Technological representativeness
Technology description including background system This EPD is based on a cradle-to-gate LCA, in which 100 weight-% has been accounted for. B6 and B7 are assessed to be not relevant. The general rules for the exclusion of inputs and outputs follows the requirements in EN 15804, 6.3.5, where the total of neglected input flows per module shall be a maximum of 5 % of energy usage and mass and 1 % of energy usage and mass for unit processes. Thatched roofs do not fall within the purview of any standardized technical specifications (hEN or EAD) as stipulated by the construction products regulation (EU regulation 305/2011). Consequently, there are no prescribed essential characteristics specified for these roofs. Further technical information can be obtained by contacting the manufacturer or on the manufacturers website: https://www.carlofchristensen.dk. Foreground system: The product is produced using Danish energy mix in where the energy is used, typically “production”. Background system: Upstream processes are modelled using D type. Downstream processes are modelled using mix type.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 33
  • 0.093
  • 0.00874
  • 16.5
  • 0.357
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.0126
  • 0
  • 0.00143
  • -696
Input
  • 669
  • 0
  • 0
  • 335
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 335
Input
  • 702
  • 0.093
  • 0.00874
  • 351
  • 0.357
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.0126
  • 0.0689
  • 0.00143
  • -362
Input
  • 356
  • 25.6
  • 0.03
  • 0
  • 0.281
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 4.07
  • 376
  • 0.27
  • -127
Input
  • 5.6
  • 0
  • 5.6
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 5.6
Input
  • 362
  • 25.6
  • 5.63
  • 0
  • 0.281
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 4.07
  • 376
  • 0.27
  • -122
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.25
  • 0.00346
  • 0.0000535
  • 0
  • 0.0011
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.00114
  • 0.0261
  • -0.0000744
  • -0.0228
Output
  • 0.00537
  • 0.000602
  • 0.00000265
  • 0
  • 0.0000166
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.00539
  • 5.15
  • 0.807
  • -0.00329
Output
  • 20.3
  • 1.19
  • 0.45
  • 0
  • 0.0158
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.636
  • 1.28
  • 0.0237
  • -1.43
Output
  • 0.00172
  • 0.0000079
  • 1.51E-7
  • 0
  • 9.43E-8
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 7.39E-7
  • 0.00000467
  • 6.18E-8
  • -0.0000956
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.862
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0.513
  • 0
  • 1.38
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 23.4
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 1.3E+2
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 186

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 337
  • 24
  • 0.0285
  • 0
  • 0.264
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 3.83
  • 5.17
  • 0.254
  • -108
  • 0.0000544
  • 0.00000553
  • 1.13E-8
  • 0
  • 1.2E-7
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 6.73E-7
  • 0.00000106
  • 3.54E-8
  • -0.0000523
  • 0.227
  • 0.0037
  • 0.00000672
  • 0
  • 0.000102
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.00131
  • 0.00442
  • 0.0000782
  • -0.18
  • 3.9E-7
  • 3.69E-8
  • 3.69E-11
  • 0
  • 3.42E-10
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 4.72E-9
  • 9.36E-9
  • 2.89E-10
  • -5.47E-7
  • 0.00146
  • 0.00012
  • 0.00000136
  • 0
  • 0.00000348
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.0000198
  • 0.000167
  • 0.00000195
  • -0.00402
  • 0.0602
  • 0.000933
  • 0.00000162
  • 0
  • 0.000093
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.000516
  • 0.00241
  • 0.0000281
  • -0.0115
  • 0.658
  • 0.00948
  • 0.0000185
  • 0
  • 0.000328
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.00534
  • 0.022
  • 0.000299
  • -0.489
  • 0.228
  • 0.00574
  • 0.00000436
  • 0
  • 0.0000984
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.00184
  • 0.00589
  • 0.000108
  • -0.0606
  • -62.2
  • 0.00155
  • 0.00012
  • 40.2
  • -0.0157
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.00016
  • 33.5
  • 0.00153
  • -75.1
  • 22.8
  • 1.69
  • 0.00171
  • 0
  • 0.0203
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.678
  • 0.496
  • 0.014
  • -12.4
  • 0.011
  • 0.000836
  • 0.00000543
  • 0
  • 0.0187
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.000131
  • 0.000168
  • 0.0000246
  • -0.00672
  • -39.4
  • 1.69
  • 0.00184
  • 40.2
  • 0.0232
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.678
  • 34
  • 0.0155
  • -87.5
  • 127
  • 11.5
  • 0.00506
  • 0.0163
  • 0.215
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 1.06
  • 49.6
  • 0.000257
  • -0.39
  • 1.61E-7
  • 7.71E-10
  • 8.4E-13
  • 0
  • 1.98E-11
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 1.49E-10
  • 3.33E-9
  • 2.03E-11
  • -7.23E-10
  • 4.62E-7
  • 1.71E-8
  • 2.37E-11
  • 2.9E-10
  • 3.42E-10
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 3.39E-9
  • 1.17E-7
  • 1.23E-10
  • -1.39E-7
  • 0.327
  • 0.0325
  • 0.000643
  • 0
  • 0.000389
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 2.72
  • 0.0185
  • 0.145
  • -49.1
  • 0.00000178
  • 1.26E-7
  • 4.77E-11
  • 0
  • 2.27E-9
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 3.48E-8
  • 6.14E-8
  • 2.64E-9
  • -0.0000015
  • 107
  • 14.5
  • 0.0392
  • 0
  • 0.99
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 1.89
  • 4.27
  • 0.356
  • -112
  • 1.23
  • 0.0991
  • 0.000273
  • 0
  • 0.032
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0.0361
  • -0.253
  • -0.00391
  • -0.826