Durus EasyFinish
Technical purpose of product or process Durus EasyFinish is used as secondary reinforcement in concrete matrices and is added in a rate of 2-6kg/m³ of concrete depending on the application. Typical application areas are foundations, floor slabs and precast concrete elements. The EasyFinish packaging is designed to be dosed as such in the concrete batching plant or the concrete mixing truck. Reinforcement of ready-mix, precast or sprayed concrete.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 1.4.06 Mineralische Baustoffe / Mörtel und Beton / Betonzusatzmittel
General comment on data set Durus EasyFinish is used as secondary reinforcement in concrete matrices and is added in a rate of 2-6kg/m³ of concrete depending on the application. Typical application areas are foundations, floor slabs and precast concrete elements. The EasyFinish packaging is designed to be dosed as such in the concrete batching plant or the concrete mixing truck. Reinforcement of ready-mix, precast or sprayed concrete
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • gross density: 912.0 kg/m^3
    • conversion factor to 1kg: 1.0 -
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.17 kg
Time representativeness
Data set valid until 2025
Time representativeness description valid from 2020-06-11 - 2025-06-11
Technological representativeness
Technology description including background system mass for unit processes. Product stage (A1-A3) includes: A1 – Extraction and processing of raw materials A2 – Transport to the production site A3 – Manufacturing processes The product stage comprises the acquisition of all raw materials, products and energy, transport to the production site and packaging. The LCA results are declared in aggregated form for the product stage, which means, that the submodules A1, A2 and A3 are declared as one module A1-A3. Durus EasyFinish production: PP granulates and additives are gravimetrically dosed and mixed in the extruder feeder hopper. This mixture is molten and blended in an extruder to a homogeneous polymer melt. After filtration and metering, the liquid polymers are extruded trough a die plate where the filaments are created. In order to increase the mechanical strength of the filaments, they are drawn and annealed in multiple steps. These high strength filaments undergo a surface deformation step in a consecutive step. In the next step the filaments are simultaneously wound into bundles, wrapped with water soluble film and cut to length to form pucks. Edge trim waste is regrinded and re-fed to the extruder. In the last process step, the pucks are stacked and packed in paper bags of 2-4 kg/ per piece. After pallet stacking of the bags, the pallet is wrapped with PE stretch film and provided by a cover. Construction process stage (A4-A5) includes: A4 – Transportation from the Adfil factory in Belgium to a construction site in Europe. A5 – Accounts for the environmental impacts related to the incineration of the packaging waste handled at the construction site. No impacts are associated with adding Durus EasyFinish to the concrete mix. Use stage (B1-B7) includes: Modules are not relevant for this product. End of Life (C1-C4) includes: C1 – Deconstructing the concrete structure using a mechanical demolition hammer. C2 – Transportation of the demolished concrete parts to a waste processing site. C3 – The concrete with Durus EasyFinish embedded is grinded to smaller pieces at the size of gravel and used as road fill using a mechanical grinding machine. C4 – All disposal processes are handled in C1-C3, and no disposal emissions occur in this module, as the entire product is assumed recycled and used as road fill. Re-use, recovery and recycling potential (D) includes: D – Durus EasyFinish is used as road fill and credited the amount of replaced gravel. Energy credits from incineration of the packaging are also accounted for in this module.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 4.74
  • 0.0656
  • 0.00213
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.0000612
  • 0.00654
  • 0.00196
  • 0
  • -0.0332
Input
  • 0.781
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 5.52
  • 0.0656
  • 0.00213
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.0000612
  • 0.00654
  • 0.00196
  • 0
  • -0.0332
Input
  • 77.8
  • 1.14
  • 0.0114
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.000138
  • 0.114
  • 0.00442
  • 0
  • -0.312
Input
  • 43.2
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 121
  • 1.14
  • 0.0114
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.000138
  • 0.114
  • 0.00442
  • 0
  • -0.312
Input
  • 0.0198
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0.483
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0115
  • 0.0000764
  • 0.000118
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 7.07E-8
  • 0.00000762
  • 0.00000227
  • 0
  • 0.0000776
Output
  • 3.09E-8
  • 5.27E-8
  • 1.31E-11
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 5.71E-14
  • 5.25E-9
  • 1.83E-12
  • 0
  • -4.02E-10
Output
  • 0.0211
  • 0.000181
  • 0.000803
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 9.79E-8
  • 0.000018
  • 0.00000314
  • 0
  • -0.0292
Output
  • 0.00308
  • 0.0000021
  • 6.21E-7
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 2.09E-8
  • 2.09E-7
  • 6.71E-7
  • 0
  • -0.0000252
Output
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.027
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 77.7
  • 1.13
  • 0.0114
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.000138
  • 0.113
  • 0.00442
  • 0
  • -0.312
  • 7.29E-7
  • 6.87E-9
  • 1.05E-10
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 2.27E-12
  • 6.86E-10
  • 7.28E-11
  • 0
  • -2.56E-10
  • 0.0041
  • 0.000104
  • 0.00000773
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.73E-8
  • 0.0000104
  • 5.55E-7
  • 0
  • -0.000145
  • 1.12E-9
  • 1.56E-17
  • 6.69E-18
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.73E-19
  • 1.56E-18
  • 5.53E-18
  • 0
  • -1.47E-9
  • 0.00000549
  • 2.59E-7
  • 1.08E-9
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 2.1E-11
  • 2.58E-8
  • 6.72E-10
  • 0
  • -8.22E-9
  • 0.00109
  • 0.000033
  • 0.00000257
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 3.85E-9
  • 0.00000329
  • 1.23E-7
  • 0
  • -0.0000164
  • 0.0116
  • 0.00039
  • 0.0000359
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 4.04E-8
  • 0.0000389
  • 0.0000013
  • 0
  • -0.00017
  • 0.00452
  • 0.0000869
  • 0.00000695
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.05E-8
  • 0.00000867
  • 3.38E-7
  • 0
  • -0.0000522
  • -0.0737
  • -0.000143
  • 0.043
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 2.62E-8
  • -0.0000142
  • 8.39E-7
  • 0
  • 0.0392
  • 2.03
  • 0.0848
  • 0.00388
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.00000785
  • 0.00846
  • 0.000252
  • 0
  • -0.0185
  • 0.00105
  • 0.000688
  • 5.83E-7
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.14E-8
  • 0.0000686
  • 3.65E-7
  • 0
  • -0.0000072
  • 1.95
  • 0.0854
  • 0.0469
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.00000789
  • 0.00851
  • 0.000253
  • 0
  • 0.0208
  • 0.344
  • 0.000829
  • 0.005
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.00000171
  • 0.0000827
  • 0.0000548
  • 0
  • 0.00346

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 40.1
  • 0.849
  • 0.00541
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.000059
  • 0.0846
  • 0.00189
  • 0
  • -0.0696
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 8.82E-10
  • 1.75E-11
  • 3.32E-13
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.63E-15
  • 1.75E-12
  • 5.23E-14
  • 0
  • -2.24E-12
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.67E-8
  • 8.94E-10
  • 1.56E-11
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 6.01E-14
  • 8.91E-11
  • 1.93E-12
  • 0
  • -1.48E-10
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 0.438
  • 0.00031
  • 0.0000962
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.00000344
  • 0.0000309
  • 0.00011
  • 0
  • -0.000618
Potential incidence of disease due to PM emissions (PM) 2
  • 3.91E-8
  • 6.68E-10
  • 4.38E-11
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 1.45E-13
  • 6.66E-11
  • 4.66E-12
  • 0
  • -1.83E-9
Potential Soil quality index (SQP) 2
  • 19.3
  • 0.398
  • 0.0031
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • 0.000044
  • 0.0397
  • 0.00141
  • 0
  • -0.00605